Case: T07FR00563

Parcel: 12201024G


Addresses:

3934 E GRANT RD


Inspection Status: Approved

Inspection History: VIOL - MEANS OF EGRESS

Case Number - T07FR00563

Inspection Description - VIOL - MEANS OF EGRESS

Inspection Status - Approved

Date Description Inspector Results Comments
04/17/2007 VIOL - MEANS OF EGRESS Approved
03/23/2007 VIOL - MEANS OF EGRESS Violation Blocked exit:
1003.6 Means of egress continuity. The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in
this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of a means of egress system shall not be diminished along the path of egress travel.

_______Clear exit area, and maintain it this way.
03/23/2007 VIOL - MEANS OF EGRESS Violation Emergency lighting:
TFC 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premise's electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas:

______Fix all inoperative emergency lights.
03/23/2007 VIOL - MEANS OF EGRESS Violation Thumb latch on both back doors:
TFC 1008.1.8.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: [2.2]. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background.

______Place above-mentioned sign on or above both back doors in an approved manner. [and keep unlocked during business hours]
Note: this is because of the "panic hardware" present on the doors.


Re-inspection date scheduled on or after April 10, 2007.
If you have any questions or concerns please call me at 791-4502
Thank you,

_____________________________________________
Brian Cobb, Inspector, Tucson Fire Department


___________________I have received a copy of this inspection report.
Building Representative


_____________________________________________
Captain