Case: T07FR00469

Parcel: 12317201C


Addresses:

1449 N CHERRY AV


Inspection Status: Violation

Inspection History: VIOL - MEANS OF EGRESS

Case Number - T07FR00469

Inspection Description - VIOL - MEANS OF EGRESS

Inspection Status - Violation

Date Description Inspector Results Comments
03/15/2007 VIOL - MEANS OF EGRESS Violation 1011.2 Illumination. Exit signs shall be internally or externally illuminated. Cause ALL of your exit signs to be illuminated 1)In North hall way, 2) NW hall, 3) Upstairs in E (near interior stairwell).
03/15/2007 VIOL - MEANS OF EGRESS Violation 1011.1 Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Replace exit signs removed in the 1)downstairs corridor (nearest to the kitchen/ living room.) 2) SE corridor (upstairs) leading to exterior exit stairs.
03/15/2007 VIOL - MEANS OF EGRESS Violation 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. Cause your emergency lighting to be powered:All dorm exit corridors ( hallways ).
03/15/2007 VIOL - MEANS OF EGRESS Violation 1008.1.8.1 Hardware. Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. Replace handle on sliding glass door on W side of building near kitchen.
03/15/2007 VIOL - MEANS OF EGRESS Violation 1008.1.8.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted. Remove surface bolt on kitchen pantry door.