Inspection History Details
Inspection Status: Violation
Inspection History: VIOL - MEANS OF EGRESS
Case Number - T07FR00469
Inspection Description - VIOL - MEANS OF EGRESS
Inspection Status - Violation
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/15/2007 | VIOL - MEANS OF EGRESS | Violation | 1011.2 Illumination. Exit signs shall be internally or externally illuminated. Cause ALL of your exit signs to be illuminated 1)In North hall way, 2) NW hall, 3) Upstairs in E (near interior stairwell). | |
| 03/15/2007 | VIOL - MEANS OF EGRESS | Violation | 1011.1 Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Replace exit signs removed in the 1)downstairs corridor (nearest to the kitchen/ living room.) 2) SE corridor (upstairs) leading to exterior exit stairs. | |
| 03/15/2007 | VIOL - MEANS OF EGRESS | Violation | 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. Cause your emergency lighting to be powered:All dorm exit corridors ( hallways ). | |
| 03/15/2007 | VIOL - MEANS OF EGRESS | Violation | 1008.1.8.1 Hardware. Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. Replace handle on sliding glass door on W side of building near kitchen. | |
| 03/15/2007 | VIOL - MEANS OF EGRESS | Violation | 1008.1.8.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted. Remove surface bolt on kitchen pantry door. |