Case: T07FR00458

Parcel: 13707037A


Addresses:

330 W NEBRASKA ST


Inspection Status: Approved

Inspection History: INSP - FULL

Case Number - T07FR00458

Inspection Description - INSP - FULL

Inspection Status - Approved

Date Description Inspector Results Comments
04/12/2007 INSP - FULL Approved approved
03/08/2007 INSP - FULL Violation 1). Currently there are many plastic decorations hanging from wall. These seem to be combustible, if they are these are in violation of IFC 805.1 which sates:

DECORATIONS AND TRIM
805.1 General. In occupancies of Groups A, E, I and R-1 and
dormitories in Group R-2, curtains, draperies, hangings and
other decorative materials suspended from walls or ceilings
shall be flame resistant in accordance with Section 805.2 and
NFPA 701 or be noncombustible.
In Groups I-1 and I-2, combustible decorations shall be
flame retardant unless the decorations, such as photographs
and paintings, are of such limited quantities that a hazard of fire
development or spread is not present. In Group I-3, combustible
decorations are prohibited.
805.1.1 Noncombustible materials. The permissible
amount of noncombustible decorative material shall not be
limited.
805.1.2 Flame-resistant materials. The permissible
amount of flame-resistant decorative materials shall not exceed
10 percent of the aggregate area ofwalls and ceilings.
Exception: In auditoriums of Group A, the permissible
amount of flame-resistant decorative material shall not
exceed 50 percent of the aggregate area ofwalls and ceiling
where the building is equipped throughout with an
automatic sprinkler system in accordance with Section
903.3.1.1, and where the material is installed in accordance
with Section 803.3 of the International Building
Code.


Please show proof that hangings are accordance with IFC 805.1, or remove all decorations.