Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
Permit Number - T07EL02209
Inspection Description - ELECTRIC - FINAL
Inspection Status - Denied
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/29/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. SUPPORT #4 COPPER ACROSS ROOF 2. SUPPORT NEW BOX & CAR FLEX ON ROOF DATE STAMPED 10/3/07 3. IDENTIFY CIRCUITS IN JUNCTION BOX TO VERIFY SHARED NEUTRALS 4. CORRECTLY IDENTIFY UNGROUNDED CONDUCTORS 5. CLEAN PAINT UNDER LUG 250.12 6. TIGHTEN LOOSE FITTINGS 7. CAR FLEX SUPPORT TO BE WITHIN 12" OF BOX 8. SECURE NM CABLE TO BOX 312.5(C) 9. FINISH PREVIOUS ITEMS 7, 8, 10 & 13 |
|
| 02/22/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. COMPLETELY DRIVE GROUND RODS 2. INSTALL LISTED MAST BRACING 3. ONE NEUTRAL PER TERMINAL ON NEUTRAL BAR 4. GROUND LUG NOT LISTED FOR 2 #4 TERMINATION 5. PROVIDE LADDER FOR INSPECTION 6. INSTALL BONDING BUSHING AT REDUCING WASHERS 7. CANNOT USE YELLOW WIRES FOR NEUTRAL NEUTRAL #6 AND SMALLER TO BE IDENTIFIED ALONG ENTIRE LENGTH 8. GROUND BELL BOX 9. INSTALL PROPER COVER ON GFI RECEPTACLE 10. INSTALL CONNECTOR ON ROMEX ENTERING BACK OF BELL BOX 11. CANNOT VERIFY GAS & WATER BOND 12. MAKE NEUTRAL CLOSER TO WEATHER HEAD 13. NEED DETAILED PANEL SCHEDULE NOT JUST GEN. LIGHTS AND RECEPTS. 14. SERVICE ENERGIZED PRIOR TO APPROVALS |