Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/18/2008 | ELECTRIC - FINAL | Approved | ||
| 05/21/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. BOND JUNCTION BOX 2. FILL UNUSED PORTION OF OPENING IN BACK OF PANEL WITH A NON-COMBUSTIBLE PRODUCT 3. ONLY ONE NEUTRAL CONDUCTOR TO A TERMINAL LUG 4. PLEASE VERIFY PERMIT FOR NEW WIRING TO INTERIOR 5. RECEPTACLE COVER TO BE WEATHERPROOF - 406.8 6. USE CORRECT SIZE BREAKER AMPACITY FOR NM/UF CABLES 7. PROTECT CONDUCTORS LARGER THAN #4 |
|
| 12/27/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) RECALL AFTER CROSSOVER |
|
| 12/21/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CONDUCTORS TO BE MARKED SUN LIGHT RESISTANT AND LISTED 2) USE AN APPROVED MAST BRACE KIT 3) GROUNDING ELECTRODE CONDUCTOR TO TERMINATE TO GROUNDED CONDUCTOR TERMINALS 4) ADDRESS LABEL TO BE PERMANENT METAL LABEL 5) PLEASE VERIFY GAS BOND |