Permit: T07EL02151

Parcel: 130052700


Addresses:

2052 E SILVOSA ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
04/23/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
03/18/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. RISER CONDUCTORS NOT COLOR CODED ON ROOF
APPEARS TO HAVE INSULATION DAMAGE, ALSO, MUST BE MARKED SUNLIGHT RESISTANT PER NEC.
2. ROMEX PASSING INTO BOX & BELOW PANEL NOT TERMINATED WITH APPROVED CONNECTOR, BOX OVERFILL
BRANCH NEUTRALS MUST BE RUN INTO PANEL AND NOT GANGED IN J-BOX, GROUND JUST TWISTED TOGETHER NO WIRE NUT OPEN HOLES IN BOTTOM OF J-BOX
3. VERIFY (2) GROUND RODS 6' APART WATER & GAS BONDS
4. USE 1/4" MIN. BOLTS TO SUPPORT RISER NOT DRYWALL SCREWS
5. INSTALL PERMANENT ADDRESS LABEL
6. SUPPORT 3/4" CONDUIT
7. OBTAIN THE SERVICES OF A QUALIFIED ELECTRICIAN
8. A REINSPECTION FEE NEXT INSPECTION IF NOT COMPLIANCE
03/14/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
NEED TO REVISE PERMIT FOR SERVICE UPGRADE NOT THAT SERVICE HAS BEEN REPLACED
12/11/2007 ELECTRIC - FINAL Denied 1. EXPOSED ROMEX ON NORTH WALL OUTSIDE & STOREROOM NOT TO CODE. ALSO, RUNNING ALONG OUTSIDE WEST OR BACK WALL TO SERVICE PANEL NOT TO CODE
2. DEADFRONT MISSING IN SERVICE PANEL. PLUG HOLE ON BOTTOM.
3. INSTALL GFI PROTECTED OUTLETS OVER KITCHEN SINK AND IN BATHROOM
4. INSTALL SMOKE DETECTORS IN HALLWAY & BEDROOMS

OBTAIN THE SERVICES OF A QUALIFIED OR LICENSED ELECTRICIAN TO DO THE WORK

RECALL INSPECTION