Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/23/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 03/18/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. RISER CONDUCTORS NOT COLOR CODED ON ROOF APPEARS TO HAVE INSULATION DAMAGE, ALSO, MUST BE MARKED SUNLIGHT RESISTANT PER NEC. 2. ROMEX PASSING INTO BOX & BELOW PANEL NOT TERMINATED WITH APPROVED CONNECTOR, BOX OVERFILL BRANCH NEUTRALS MUST BE RUN INTO PANEL AND NOT GANGED IN J-BOX, GROUND JUST TWISTED TOGETHER NO WIRE NUT OPEN HOLES IN BOTTOM OF J-BOX 3. VERIFY (2) GROUND RODS 6' APART WATER & GAS BONDS 4. USE 1/4" MIN. BOLTS TO SUPPORT RISER NOT DRYWALL SCREWS 5. INSTALL PERMANENT ADDRESS LABEL 6. SUPPORT 3/4" CONDUIT 7. OBTAIN THE SERVICES OF A QUALIFIED ELECTRICIAN 8. A REINSPECTION FEE NEXT INSPECTION IF NOT COMPLIANCE |
|
| 03/14/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NEED TO REVISE PERMIT FOR SERVICE UPGRADE NOT THAT SERVICE HAS BEEN REPLACED |
|
| 12/11/2007 | ELECTRIC - FINAL | Denied | 1. EXPOSED ROMEX ON NORTH WALL OUTSIDE & STOREROOM NOT TO CODE. ALSO, RUNNING ALONG OUTSIDE WEST OR BACK WALL TO SERVICE PANEL NOT TO CODE 2. DEADFRONT MISSING IN SERVICE PANEL. PLUG HOLE ON BOTTOM. 3. INSTALL GFI PROTECTED OUTLETS OVER KITCHEN SINK AND IN BATHROOM 4. INSTALL SMOKE DETECTORS IN HALLWAY & BEDROOMS OBTAIN THE SERVICES OF A QUALIFIED OR LICENSED ELECTRICIAN TO DO THE WORK RECALL INSPECTION |