Permit: T07EL01925

Parcel: 134211080


Addresses:

6955 E JULIA ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
11/28/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
11/21/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
REPAIR DAMAGED INSULATOR ON WEATHERHEAD, BROKEN OUT, SHARP EDGES MAY CAUSE DAMAGE TO CONDUCTOR INSULATION.
11/14/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. BOND GAS & WATER PIPING NEC 250
2. SECURE GROUNDING ELECTRODE CONDUCTOR & BONDING JUMPERS TO BUILDING SURFACE NEC 250
3. MARK & UNCOVER GROUND RODS
4. USE 1/4" LUG BOLTS OR WOOD SCREWS TO SECURE MAST TO BUILDING
5. CONNECT WIRES TO OVERHEAD POSITION IN METER SECTION SEE PANEL DOOR FOR INSTRUCTIONS NEC 110
6. PROPERLY IDENTIFY NEUTRALS TO SUB-PANELS - NEC 200
7. NOT ALL STRANDS OF NEUTRAL UNDER TERMINAL IN PANEL
11/13/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*