Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/01/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 10/26/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. MAST BRACE TO BE USED AS LISTED, NOT WITH THREADLESS CONNECTORS. THREAD INTO FEET AND SECURE INTO STRUCTURE (TRUSSES) NOT JUST INTO ROOF SHEATHING. LUG BOLTS ARE PROVIDED WITH THIS KIT. 2. PANEL COVER IS NOT CLOSING CORRECTLY OTHER CORRECTIONS OK |
|
| 10/24/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : 1. BOND GAS TO COLD WATER PIPE, NOT HOT AND SECURE BOND WIRE 2. IDENTIFY PANEL DIRECTORY 3. NEUTRAL TO SUB-PANEL IN SERVICE TO BE WHITE AND INSULATED 4. INSTALL A LISTED GUY KIT FOR SERVICE MAST NOTE: SERVICE ENERGIZED BEFORE APPROVAL |