Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T07EL01831
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/30/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
10/26/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ROMEX CANNOT BE RUN IN CONDUIT 2) SET SCREW CONNECTORS NOT PERMITTED WHERE EXPOSED TO WEATHER 2) HANDY BOXES NOT WEATHER PROOF 3) BUBBLE COVERS REQUIRED WHERE RECEPTACLES NOT PROTECTED FROM WEATHER, ETC... 4) SEE MANUFACTURERS INSTRUCTIONS FOR SMOKIES |
|
10/11/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. INSTALL MISSING SWITCH/RECEPTACLE WALL PLATES 2. INSTALL SMOKE DETECTORS IN BEDROOMS PER MANUFACTURES INSTRUCTIONS. PLEASE HAVE INSTRUCTIONS ON SITE FOR REINSPECTION 3. BATHROOM RECEPTACLES TO BE GFI PROTECTED 4. KITCHEN COUNTER RECEPTACLES TO BE GFI PROTECTED 5. HAVE WIRES STICKING OUT OF WALL IN LAUNDRY ROOM 6. HAVE ILLEGAL WIRING THROUGHOUT HOUSE, BACK PORCH, SHED, NEEDS TO BE REMOVED OR INSTALLED PER CODE. HAVE QUALIFIED ELECTRICIAN GO THROUGH ENTIRE PROPERTY 7. RECALL WHEN READY |