Inspection History: ELECTRIC - SERVICE UPGRADE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/11/2007 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO CORRECTIONS MADE A REINSPECTION FEE WILL BE ASSESSED NEXT INSP. IF NOT IN COMPLIANCE |
|
| 10/05/2007 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SUPPORT RISER CONDUIT. USE 1/4" MIN. BOLTS 2. STRAP #4 BARE CONDUCTOR TO WALL OF HOUSE 3. NEED TO VERIFY WATER & GAS PIPE BOND 4. EXT. CORD GOING TO SHED IS NOT WIRED TO CODE AND COULD BE HAZARDOUS OR CAUSE FIRE. REMOVE PRIOR TO NEXT INSPECTION (WIRED INTO PORCH LIGHT) NO ANSWER AT DOOR COULD NOT RETRIEVE MESSAGE (IVR DOWN) |