Permit: T07EL01695

Parcel: 119042800

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
10/24/2007 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection :*
10/19/2007 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. INSPECTORS PHONE OUT OF ORDER AT THIS TIME. UNLOCK GATES WHEN CALLING FOR INSPECTION
2. PROVIDE LADDER FOR ROOF INSP.
3. SEE NOTE #1 & 2
10/16/2007 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection :
There is no access to the site.| 920*
10/10/2007 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. UNIT #2 NOT WIRED PER CODE, OBTAIN PERMIT AND APPROVED PLAN, OBTAIN THE SERVICES OF A QUALIFIED ELECTRICIAN TO BRING UP TO CODE COMPLIANCE ALSO, A GROUNDING ELECTRODE SYSTEM REQUIRED.
2. NEED TO VERIFY RISER CONDUCTORS MATERIAL & SIZE
3. BOND BUSHING REQUIRED AT 1 1/4" TERM. NO CHASE NIPPLES! ALSO ON SIDE 3/4"
4. INSTALL A SPLIT BOLT BETWEEN GROUNDING ELECTRODE CONDUCTORS FOR UNIT #1 & #2

UNITS ENERGIZED PRIOR TO CLEARANCE