Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/02/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 09/26/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* - #4 BARE TO GROUND RODS IS A TRIP HAZARD, RUN UNDER SIDEWALK OR NOTCH CONCRETE - 240 OUTLET UNDER SERVICE MUST HAVE W/O COVER & BOX - ALL OPEN WIRING (ROMEX) IN STOREROOM TO BE PROTECTED BY RACEWAYS OR DRYWALL - PLEASE CALL FOR FINAL INSP. WHEN DONE |
|
| 09/07/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. INSTALL SMOKE DETECTORS IN BEDROOMS PER MANUFACTURES INSTRUCTIONS 2. HALLWAY SMOKE DETECTOR APPEARS NOT TO BE WORKING 3. BATHROOM RECEPTACLES TO BE GFI PROTECTED 4. OPEN WIRING UNDER KITCHEN SINK 5. INSTALL PLATE ON RECEPTACLE UNDER SINK 6. MISSING DEAD FRONT ON SERVICE PANEL 7. IT APPEARS SERVICE PANEL HAS NO GROUNDING ELECTRODES OR GROUNDING ELECTRODE CONDUCTOR 8. INSTALL FILLER PLATE AT OPEN BKR POSITION AT GARAGE PANEL 9. INSTALL MISSING PLATES & REPLACE BROKEN PLATES IN GARAGE 10. GARAGE PANEL NOT PROPERLY GROUNDED. |