Permit: T07EL01631

Parcel: 132163100

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T07EL01631

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/02/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
09/26/2007 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
- #4 BARE TO GROUND RODS IS A TRIP HAZARD, RUN UNDER SIDEWALK OR NOTCH CONCRETE
- 240 OUTLET UNDER SERVICE MUST HAVE W/O COVER & BOX
- ALL OPEN WIRING (ROMEX) IN STOREROOM TO BE PROTECTED BY RACEWAYS OR DRYWALL
- PLEASE CALL FOR FINAL INSP. WHEN DONE
09/07/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. INSTALL SMOKE DETECTORS IN BEDROOMS PER MANUFACTURES INSTRUCTIONS
2. HALLWAY SMOKE DETECTOR APPEARS NOT TO BE WORKING
3. BATHROOM RECEPTACLES TO BE GFI PROTECTED
4. OPEN WIRING UNDER KITCHEN SINK
5. INSTALL PLATE ON RECEPTACLE UNDER SINK
6. MISSING DEAD FRONT ON SERVICE PANEL
7. IT APPEARS SERVICE PANEL HAS NO GROUNDING ELECTRODES OR GROUNDING ELECTRODE CONDUCTOR
8. INSTALL FILLER PLATE AT OPEN BKR POSITION AT GARAGE PANEL
9. INSTALL MISSING PLATES & REPLACE BROKEN PLATES IN GARAGE
10. GARAGE PANEL NOT PROPERLY GROUNDED.