Permit: T07EL01331

Parcel: 122090110


Addresses:

3902 E LOUIS LN #01

Inspection Status: Denied

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
08/13/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
NEW WORK ADDED:
1. PLEASE ADD NEW CIRCUIT TO PERMIT
2. LABEL BREAKER
3. USE APPROVED FITTINGS
4. CORRECTLY SUPPORT CONDUITS
5. GROUNDING EQUIPMENT CONDUCTOR TO BE
SIZED PER 250.122
6. PLEASE VERIFY PERMIT FOR NEW AC UNIT
07/24/2007 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. BOND BUSHINGS NEEDED IN GUTTER ON NIPPLES & RISER
HUB TO BE LISTED FOR BONDING
2. RISER HARDWARE TO BE 1/4" MINIMUM
3. TIGHTEN LOOSE FITTINGS