Permit: T07EL01324

Parcel: 115201160


Addresses:

1960 W LINDEN ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/25/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
10/04/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) UPGRADE SERVICE TO 100 AMP MINIMUM AND BRING MAST AND GROUNDING UP TO CODE. WILL NEED LICENSED ELECTRICAL CONTRACTOR AND SEPERATE PERMIT FOR NEW SERVICE
2) INSTALL SMOKE DETECTORS MINIMUM 36" FROM VENTS AND PER MANUFACTURERS INSTRUCTIONS
3) INSTALL ALL DEVICE COVER PLATES
10/01/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
09/25/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
There is no access to the site.| 920*
NO ANSWER AT DOOR - UNIT LOCKED
A REINSPECTION FEE WILL BE ASSESSED NEXT INSP. IF NO ACCESS OR CONTACT PERSON PH#
07/18/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. INSTALL NEW AND WORKING SMOKE DETECTORS IN EACH BEDROOM AND HALLWAY MINIMUM 36" FROM HVAC VENTS AND ON CEILINGS.
2. INSTALL ANY MISSING SWITCH OR RECEPTACLE COVERS
3. HAVE BROKEN LIGHT FIXTURE AND OPEN WIRING IN LAUNDRY ROOM
4. SERVICE CONDUCTORS TO LOW TO GRADE IN BACKYARD
RECOMMEND A SERVICE UPGRADE.