Permit: T07EL01233

Parcel: 13307008A

Inspection Status: Not ready for Inspection

Inspection History: ELECTRIC - FINAL

Permit Number - T07EL01233

Inspection Description - ELECTRIC - FINAL

Inspection Status - Not ready for Inspection

Date Description Inspector Results Comments
08/27/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1. BOXES NEED AT WINDOW WALL
2. STAPLE NM CABLE WITHIN 8" OF BOXES
3. PROTECT CABLE INTO WALL ALSO, BOX TO BE ACCESSIBLE
4. APPROVED EXTENDER RINGS AT COMBUSTIBLES
5. EXPOSED NM CABLE
6. GROUNDED RECEPTACLE ON UNGROUNDED SYSTEM
07/23/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PLEASE VERIFY PERMITS FOR NEW WIRING TO INTERIOR
2. BATHROOM RECEPTACLES TO BE GFCI PROTECTED
3. REPLACE BAD SMOKE DETECTOR - HALL
4. NEED SMOKE DETECTOR ALL BEDROOMS
5. WE HAVE GROUNDED RECEPTACLES ON AN UNGROUNDED SYSTEM
6. MISSING & BROKEN COVER PLATES
7. LABEL BREAKERS
8. RESUPPORT EQUIPMENT FOR WELL PUMP
9. PLEASE OPEN GARAGES TO INSPECT
07/20/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
There is no access to the site.| 920*
LOCKED -- NO ACCESS