Permit: T07EL01190

Parcel: 128072320


Addresses:

6132 E ELI ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
06/10/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
01/24/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. INSTALL BREAKER LISTED FOR USE IN PANEL
TWIN BREAKER NOT LISTED TO BE USED IN PANEL
2. INSTALL 4 WIRE FEED, CORD CAP & RECEPTACLE FOR NEW DRYER CIRCUIT
3. OUTDOOR RECEPTACLE TO BE GFI PROTECTED
4. STRAP EMT WITHIN 3' OF CONNECTION POINTS
5. INSTALL MISSING K.O IN BELL BOX
07/26/2007 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) REMOVE OLD SERVICE FROM HOUSE AFTER TEP SWING OVER
2) RECALL WHEN READY