Permit: T07EL01171

Parcel: 106011350


Addresses:

3703 N 1ST AV #32


Inspection Status: Denied

Inspection History: ELECTRIC - FINAL

Permit Number - T07EL01171

Inspection Description - ELECTRIC - FINAL

Inspection Status - Denied

Date Description Inspector Results Comments
06/26/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BOND WIRE TO WATER AT SERVICE
2) TO BE SAME SIZE AS OLD ONE (#2 COPPER)
3) TO BE SECURED TO WALL AND PAINT WALL COLOR FOR PROTECTION
4) TIGHTEN ALL CONNECTIONS FOR BOND CLAMP ON WATER PIPE
5) ALL ELSE OK
06/20/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. REPAIR/REPLACE GROUNDING/BONDING CONDUCTORS AT SERVICE.
2. INSTALL FRONT PORCH BULB & GLOBE
3. SMOKE DETECTORS TO BE 36" FROM VENTS