Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/16/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 10/12/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 10/04/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 3 WIRE RECEPTACLES SHOW OPEN GROUND-GFI PROTECT OR USE 2 WIRE RECEPTACLES 2) CHECK SAME CORRECTIONS #3 APT. 3) WHERE IS DNR REPORT ? |
|
| 09/13/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* SEE WRITE UP UNIT #3 |
|
| 09/07/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* DOOR LOCKED |
|
| 08/28/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PARTIAL INSPECTION 1. AT SERVICE DISCONNECT - HUB TO BE RAIN TIGHT, IDENTIFY DISCONNECT WITH SOMETHING SUITABLE FOR ENVIRONMENT - NOT SHARPIE, ROMEX SHEATHING TO EXTEND INTO ENCLOSURE AND USE PROPER ROMEX CONNECTOR. 2. INSIDE UNIT - INSTALL NEW SMOKE DETECTORS IN BEDROOM AND OUTSIDE OF BEDROOM (BATTERY OK) MINIMUM 36" FROM VENTS AND ON CEILINGS. REPLACE ALL PAINTED OVER DEVICES INSTALL PROPERLY SIZED FUSES FOR BRANCH CKT'S SECURE BASEBOARD HEATERS TO WALLS PROVIDE ORIGINAL DNR VIOLATION REPORT CHECK THESE IN UNIT #4 ALSO, ELECTRICAL CONTRACTOR TO PROVIDE COMPLETE DESCRIPTION OF WORK DONE. |