Inspection Status: Denied
Inspection History: ELECTRIC - FINAL
Permit Number - T07EL01071
Inspection Description - ELECTRIC - FINAL
Inspection Status - Denied
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/22/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. WIRING IS SET UP INCORRECTLY BEYOND PEDESTAL, CORD IS PLUGGED INTO 120 VOLT TRAVEL TRAILER OUTLET -- WIRED FOR 240V BEYOND PEDESTAL. 2. A REINSP. FEE WILL BE ASSESSED NEXT INSP. IF NOT CORRECTED. |
|
06/18/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. USE SEALTITE CONNECTOR AT BOX TERMINATION 2. USE CORRECT WIRING TO SUB-PANEL (SHOULD BE 4-WIRE) 3. NO SMOKE DETECTOR IN BEDROOM 4. WIRING NOT CORRECT IN NEW SUB-PANELS A. ISOLATE GROUNDS & NEUTRALS B. USE APPROVED CONNECTORS OBTAIN THE SERVICES OF A QUALIFIED ELECTRICIAN |
|
06/12/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PLUG OPENINGS IN PEDESTAL WHERE BREAKER MISSING 2. BREAKER BOX ON M.H MISSING DEAD FRONT COVER, ALSO, CORD NOT WIRED CORRECTLY. 3. INSTALL WORKING SMOKE DETECTORS, INSTALL MISSING COVER PLATES FOR DEVICES. 4. COVER MISSING TO SUB-PANEL INSIDE |