Permit: T07EL00971

Parcel: 121010530


Addresses:

5971 E SENECA ST

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
06/04/2007 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection :*
06/01/2007 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. CANNOT USE WHITE CONDUCTOR AS PHASE CONDUCTOR ONLY IF PART OF CABLE ASSEMBLY PER NEC 200.7
2. WHERE IS GROUNDED (NEUTRAL) CONDUCTOR FOR DRYER?
HAVE 4 PRONG DRYER RECEPTACLE BUT HAVE NO NEUTRAL.
CANNOT USE GROUNDING CONDUCTOR FOR NEUTRAL.
SEE NEC 250.134, 250.138, 250.104, 250.142
05/30/2007 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection :
There is no access to the site.| 920*
GATES LOCKED. NO ACCESS TO BACKYARD.
RANG DOORBELL NO ONE ANSWERED
05/24/2007 ELECTRIC - SERVICE UPGRADE Not ready for Inspection IVRS - Inspection :*