Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/04/2007 | ELECTRIC - SERVICE UPGRADE | Approved | IVRS - Inspection :* | |
| 06/01/2007 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CANNOT USE WHITE CONDUCTOR AS PHASE CONDUCTOR ONLY IF PART OF CABLE ASSEMBLY PER NEC 200.7 2. WHERE IS GROUNDED (NEUTRAL) CONDUCTOR FOR DRYER? HAVE 4 PRONG DRYER RECEPTACLE BUT HAVE NO NEUTRAL. CANNOT USE GROUNDING CONDUCTOR FOR NEUTRAL. SEE NEC 250.134, 250.138, 250.104, 250.142 |
|
| 05/30/2007 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : There is no access to the site.| 920* GATES LOCKED. NO ACCESS TO BACKYARD. RANG DOORBELL NO ONE ANSWERED |
|
| 05/24/2007 | ELECTRIC - SERVICE UPGRADE | Not ready for Inspection | IVRS - Inspection :* |