Permit: T07EL00965

Parcel: 122161920


Addresses:

2032 N BAXTER DR

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/05/2007 ELECTRIC - FINAL Approved OK FINAL
09/13/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1. LB COVER NOT ACCESSIBLE
2. PLEASE VERIFY TYPE CONDUCTOR FOR SUB-PANEL
CORD NOT ALLOWED FOR PERMANENT WIRING 400.7 & 8
LIFE LINE NOT APPROVED
3. PROTECT CONDUCTORS AT NIPPLE 300.4
4. CHASE NIPPLE AT REDUCING WASHER NOT ALLOWED
USE APPROVED FITTING TO PROVIDE GROUND FAULT PATH
5. USE CORRECT SIZED KO PLUG
08/14/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) CALL FOR FINAL ONCE CHANGED OVER