Permit: T07EL00924

Parcel: 135061150

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
08/15/2007 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection :*
08/10/2007 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BOND GAS PIPING ON HOUSE SIDE OF METER
2) INSTALL BREAKERS LISTED FOR USE IN SIEMENS PANEL
3) INSTALL ANTI-OXIDATION COMPOUND ON ALUMINIUM TERMINATIONS
4) INSTALL SERVICE CONDUCTORS TO OVERHEAD POSITION IN METER SECTION. SEE INSTRUCTIONS ON PANL DOOR