Permit: T07EL00879


Addresses:

3356 S 6TH AV


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T07EL00879

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/01/2008 ELECTRIC - FINAL Approved
08/30/2007 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) WHAT IS GOING TO HAPPEN TO TEMP SERVICE EQUIPMENT? CONTRACTOR TO ENSURE THAT ONLY AUTHORIZED PERSONS TO HAVE ACCES TO ELECTRICAL EQUIPMENT
08/29/2007 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
- OK UTILITY SECTION OF SES - CALL FOR INSPECTION FOR LOAD CONNECTIONS WHEN READY
RECEIVED TORQUE LETTER
08/27/2007 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1. PROVIDE TORQUE LETTER FOR NEW SES
2. APPROVED PLANS
3. COMPLETE BONDING WATER - 250 NEC
4. USE BONDING HUBS FOR RISER TERMINATIONS TO GEAR OR
GROUND LAMPS -- 250.94
06/29/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
06/05/2007 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) TEMP POWER LOADS IN BLDG NOT CONNECTED YET
2) WATER PIPING IS BEING DEMO'ED OUT BY PLUMBING CONTRACTOR
3) IT WILL BE NECESSARY TO TIE IN TO TEMP SERVICE IF NEW PERMANENT SERVICE COMPLETE PRIOR TO NEW WATER SYSTEM INSTALLATION
4) CALL FOR INSPECTION WHEN TEMPORARY POWER WIRED UP FOR INSPECTION
05/31/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. BOND METAL RACEWAYS FOR GROUNDING ELECTRODE CONDUCTORS PER 250.64 E NEC
2. BOND WATER PIPING 250.104 NEC