Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/18/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 05/17/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. COMPLETE PREVIOUS CORRECTIONS (#1, #3) 2. THIRD CONDUCTOR FOR RANGE IS A NEUTRAL, NOT TO BE USED TO GROUND J-BOX, AND NEEDS TO BE IDENTIFIED AS A NEUTRAL -- PULL SEPARATE GROUND TO GROUND J-BOX #6 & SMALLER NEUTRAL TO BE WHITE ENTIRE LENGTH - NEC 200.6 #6 AND SMALLER GROUND GREEN OR BARE ENTIRE LENGTH NEC 250.119 |
|
| 05/16/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : 1. RELOCATE SERVICE LUGS TO OVERHEAD POSITION PER SERVICE INSTRUCTIONS -- NEC 110.3B 2. CAN'T LOCATE GROUND ROD (2ND) 3. #6 GROUND TO BE GREEN OR BARE ENTIRE LENGTH PER NEC 250.119 4. PROVIDE LADDER FOR ROOF/J-BOX ACCESS |