Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/14/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 05/11/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CONNECTION NOT COMPLETE AT AC DISCONNECT 2) DISCONNECT FITTING BETWEEN UNIT IS NOT CONNECTED EXPOSED WIRING AND DISCONNECT NOT SUPPORTED. SEE NOTE #3 AND #7 INSPECTION ON 5/7/07. CALLED BOTH PHONE NUMBERS LEFT MESSAGE |
|
| 05/08/2007 | ELECTRIC - FINAL | Cancelled | CANCELLED PER GENERAL CONTRACTOR MELODY #514-1240 | |
| 05/08/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 05/07/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* UNIT IS OCCUPIED 1. WE HAVE GROUNDED RECEPTACLES ON AN UNGROUNDED SYSTEM. 2. MISSING COVER PLATES 3. SUPPORT A.C DISCONNECT 4. SMOKE DETECTORS TO BE INSTALLED AS PER MANUFACTURES INSTRUCTIONS 5. A GFCI RECEPTACLE IS NEEDED IN BATHROOM 6. FILL UNUSED OPENINGS IN PANEL - BACK OFF & DEAD FRONT 7. RE-STRAP GROUNDING ELECTRODE CONDUCTOR TO BUILDING. |
|
| 05/04/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO KEY WRONG ADDRESS |