Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T07EL00782
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/06/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 05/08/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. INSTALL SMOKE DETECTORS IN ALL BEDROOMS PER MANUFACTURES INSTRUCTIONS 2. INSTALL GFI PROTECTION FOR BATHROOM RECEPTACLES 3. INCANDESCENT LIGHT FIXTURE IN CLOTHES CLOSET TO BE 100% ENCLOSED 4. INSTALL GFI PROTECTION FOR KITCHEN COUNTER RECEPTACLES 5. NEED TO LABEL CIRCUITS AT PANEL |
|
| 05/03/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920* 1. NO ACCESS TO UNIT 2. CALLED PHONE NUMBER LEFT MESSAGE. NO ONE ON SITE. |