Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/03/2007 | ELECTRIC - SERVICE UPGRADE | Approved | IVRS - Inspection :* | |
| 05/04/2007 | ELECTRIC - SERVICE UPGRADE | Partial Approval | IVRS - Inspection :* 1) RECALL AFTER TEP TIE IN AND REST OF WORK COMPLETE |
|
| 05/03/2007 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 05/02/2007 | ELECTRIC - SERVICE UPGRADE | Not ready for Inspection | IVRS - Inspection :* INSPECTION CANCELLED |
|
| 05/01/2007 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. BACK BRACING TO CIRCUIT PANEL INSIDE SERVICE IS BROKEN 2. MUST USE A LISTED BRACE ASSEMBLY TO HOLD RISER ABOVE ROOF -- ALSO, BRACE MUST BE BEHIND RISER OPPOSITE SIDE FROM TEP POLE 3. RISER BELOW ROOF TO HAVE 2 BRACES 4. CIRCUIT BREAKER IN SERVICE (40 AMP) WRONG TYPE 5. WATER BOND -- CORRECTLY TIE INTO EXISTING CLAMP BEING USED WRONG TYPE. |