Permit: T07EL00738

Parcel: 122060720


Addresses:

4207 E WAVERLY ST


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T07EL00738

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/01/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
05/10/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
CONNECTICUT ELECTRIC BREAKER IS NOT
LISTED TO BE USED IN A SIEMENS PANEL
SEE CIRCLED LABEL ON INSIDE COVER CHANGE OUT AND USE SIEMENS TYPE.
04/30/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. GAS METAL LINE ALSO REQUIRED TO BE BONDED
2. 2ND ROD TO GO TO GRADE
3. SIEMENS PNL DOES NOT LIST GE BREAKER
4. USE APPROVED LIST BRACE KIT -- NO EMT
5. WHITE CONDUCTOR ON AC TO BE TAPED BLACK OR RED
6. AC PERMIT?
7. EMT CONDUIT BEFORE IT GOES THRU ROOF TO BE INSTALLED ON COUPLING CORRECTLY, TIGHTEN FITTINGS, SUPPORT 3/4" EMT