Permit: T07EL00720

Parcel: 116231810


Addresses:

932 S VERDUGO AV

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
05/10/2007 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
05/08/2007 ELECTRIC - RECONNECT Cancelled CANCELLED PER OWNER RITA #889-2194
05/08/2007 ELECTRIC - RECONNECT Not ready for Inspection IVRS - Inspection :*
CANCELLED
05/07/2007 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE NOTES -- #3, #8 LAST INSP.
05/01/2007 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
NOTES:
1. INSTALL GFI RECEPTACLES OVER KITCHEN SINK AREA
2. 240 RANGE RECEPTACLE WIRING NOT INSTALLED PER CODE
3. RANGE HOOD NOT WIRED PER CODE
4. SMOKE DETECTOR TO LOW, SHOULD BE BETWEEN 6"-12" BELOW CEILING.
5. EXPOSED WIRING IN BATHROOM
6. COVER PLATES FOR SWITCHES AND RECEPTS MISSING THROUGHOUT HOUSE.
7. SMOKE DETECTOR IN BEDROOM TO LOW & TOO CLOSE TO COOLER VENT OTHER BEDROOM SMOKE DETECTOR TO LOW.
8. ROMEX FOR PORCH & CARPORT NOT TO CODE ALSO, FLUORESCENT LIGHT NOT CODE.
9. CIRCUIT BREAKERS IN SERVICE PANEL NEED TO BE SAME MANUF. (BRAND) AS PANEL.