Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/20/2007 | ELECTRIC - SERVICE UPGRADE | Approved | IVRS - Inspection :* | |
| 06/25/2007 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 05/11/2007 | ELECTRIC - SERVICE UPGRADE | Partial Approval | IVRS - Inspection :* 1) COMPLETE ITEM #1 FROM INSPECTION ON 5/4/07 2) INSTALL 2 CLAMPS ON RISER USING 1/4" HARDWARE 3) SEAL ROOF JACK 4) RECALL AFTER TEP TIE IN |
|
| 05/06/2007 | ELECTRIC - SERVICE UPGRADE | Partial Approval | IVRS - Inspection :* | |
| 04/19/2007 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. A GAS & WATER BOND IS NEEDED 2. A PERMANENT METAL ADDRESS LABEL IS NEEDED 3. RISER HARDWARE TO BE 1/4" MINIMUM AND INSTALLED AS PER MANUFACTURES INSTRUCTIONS. 4. USE A LISTED GUY BACK KIT & METHOD 5. IDENTIFY GROUNDED CONDUCTOR IN METER SECTION 6. INSTALL CONDUCTORS AS PER MANUFACTURES INSTRUCTIONS. 7. THIS IS AN UNOCCUPIED UNIT -- CROSSOVER CONNECTION CAN BE MADE -- ALL CONNECTION TO BE IN NEW PANEL 8. PLEASE VERIFY PERMITS FOR NEW WORK TO INTERIOR. |