Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T07EL00614
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/12/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
06/05/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. USE A PROPER M.H RECEPTACLE RATED BOX AT POWER CORD ATTACHMENT LISTED FOR USE THE HOMEMADE BOX IS NOT LISTED AS USED, ALSO, BARE GROUND WIRE MADE OUT OF BRAIDED #12 WIRE NOT APPROVED 2. TIE WRAP NOT APPROVED TO SUPPORT M.H BOX TO POST 3. WORK TO BE DONE BY QUALIFIED ELECTRICIAN |
|
04/11/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
04/10/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROPERLY SECURE RECEPT BOX - MUST BE RATED FOR OUTDOOR USE. CANNOT BE HUNG ON CHAIN. GROUND PROPERLY. 2. INSTALL SMOKE DETECTORS IN SLEEPING AREAS. 3. REPAIR LOOSE BOX & EXPOSED WIRING BELOW ENTRY DOOR. 4. NEED TO REFER BLD. INSPECTOR TO LOOK AT ADDITION |