Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T07EL00606
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/12/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
04/06/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ALL BREAKERS TO BE OF SAME TYPE NOT GE 2) CANNOT USE A WHITE WIRE AS A HOT 3) PLUG IN OUTLET BELOW SERVICE NOT SECURED 4) CANNOT WHITE WATER CONDUIT FOR ELECTRICAL 5) CANNOT BURY FLEX 6) SHED HAS ELECTRIC IN IT-OPEN TO INSPECT 7) SLEEPING AREAS REQUIRE SMOKE DETECTORS 8) IMPROPERLY WIRED COOLER FROM INSIDE 9) COULD NOT LOCATE INSIDE PANEL FOR INSPECTION |