Permit: T07EL00569

Parcel: 124071020

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T07EL00569

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/07/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
11/01/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
CORRECTIONS NOT COMPLETED
YOU WILL NEED TO PAY REINSPECTION FEE
DO NOT CALL BEFORE CORRECTIONS ARE COMPLETE
10/30/2007 ELECTRIC - FINAL Cancelled IVRS - RI canceled
10/30/2007 ELECTRIC - FINAL Denied 1. 2ND GROUND ROD NOT INSTALLED
2. SEVERAL CIRCUIT BREAKERS POORLY INSTALLED DO NOT CLIP ON, ON BACK SIDE
3. FRONT OUTSIDE FIXTURE BADLY INSTALLED - TO BE FLUSH AGAINST SURFACE
10/19/2007 ELECTRIC - FINAL Partial Approval 1) GROUND ROD ?
2) SMOKE DETECTOR
3) CALL FOR FINAL ONCE ENERGIZED
10/09/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
CANCELLED
08/14/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/06/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PRIOR TO ANY SERVICE RELEASE, SUPPORT ELECTRICAL SERVICE ENCLOSURE AND ITS BACKING TO STRUCTURE
2. RANGE OUTLET MUST BE 4-HOLE TYPE 4-WIRE,
SUPPORT BOX
3. WH WIRING PROPERLY FLEX FROM WALL TO WH, PROPERLY GROUND AND USE FITTING TO ENTER WH - WH MUST BE ACCESSIBLE AT ALL TIMES
4. REPAIR EXPOSED AREA AROUND RECEPTACLE UNDER KIT. SINK
5. KIT. COUNTER RECEPTS - ALL DEVICES TO BE GROUNDED EVEN DIFF. CIRCUITS ALSO, USE EXTENSION RINGS WHERE TILE USED.
6. REMOVE DISHWASHER TO EXPOSE WIRING
7. PLAN DOES NOT SHOW GARBAGE DISPOSAL OR DW MUST BE ON ITS OWN CIRCUIT -- VERIFY
8. FIT CEILING LIGHT - STAPLE W/IN 12" BOX, USE ROMEX CONN.
9. BATHROOM IMPROPERLY WIRED - NO FITTINGS AT BOXES
WIRING NOT RUN CORRECTLY - NOT PROPERLY SUPPORTED EX. FAN NOT PROPERLY WIRED - NEED 1 SOLE CIRCUIT TO RECEPT.
10. ALL ITEMS IN BEDROOM TO BE UNDER ARC FAULT
11. CLOSET LIGHT HAS TO BE 12" AWAY FROM SHELF SIDEWAYS NOT UP OR DOWN
12. PANEL SHOWS 2 CIRCUITS ADDITIONAL USED THAN PLAN
13. NEED ACCESS TO ROOF
08/02/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
COULD NOT RETRIEVE IVR MESSAGE - NOT WORKING
NO PLANS, CONTRACTOR, LOCKED
07/30/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
APPROVED PLANS FOR THIS JOB STILL NOT OBTAINED, CONTRACTOR STATES STILL IN PROCESS.
07/20/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. OPEN ONE SIDE OF WALLS & CEILING
2. OBTAIN ELECT. PLAN OF LAY WHICH MEETS CODE
06/01/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
SORRY DON'T HAVE AVAILABILITY TO MAKE A 2HR AHEAD APPOINTMENT. RECALL & WITH 30 MIN. NOTICE REQUEST AND I CAN FIT IN EASIER.
05/02/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. ID NEUTRAL USED AS UNGROUNDED CONDUCTORS IN SERVICE PANEL.
2. SUPPORT TOP SUPPORT OF RISER CONDUIT PROPERLY, WOOD BACKING IS SPLIT IN HALF
3. GROUND ALL LIGHT SWITCHES LEAVE COVERS OFF FOR INSPECTION.
4. REMOVE CEILING FANS OR COVER OVER J-BOX TO INSP. BOX
5. ARC FAULT CIRCUIT PROTECTION REQUIRED FOR BEDROOM OUTLETS. PLAN NOT COMPLETE MUST REFLECT ALL NEW INSTALLATIONS OF WIRING, DEVICES, FANS, SMOKE DETECTORS; MECHANICAL; PLUMBING
6. GARBAGE DISP. NOT WIRED
7. NO ANTI-TIP HOLDDOWN FOR RANGE
8. VERIFY WATER & GAS PIPE BONDING TO SERVICE GROUND
9. ROMEX TO BE STAPLED WITHIN 12" OF BOXES INSTALL NAIL PLATES WHERE CABLE IS WITHIN 1 1/4" FROM FACE OF STUD.
10. REMOVE ALL LIGHT FIXTURES FOR INSP. VERIFY SUPPORT FOR ROMEX.
04/23/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
GUS MAUGHAN (OWNER) 444-7379
1. UNIT HAS BEEN FULLY REMODELED WITHOUT ANY INSPECTIONS. A SEPARATE PERMIT WAS OBTAINED FOR RECONNECT AND PANEL UPGRADE -- PANEL WAS NOT UPGRADED, HOWEVER, EXISTING SERVICE SHOWS NEW WIRIING PULLED TO SERVICE - THERE IS NO INDICATION OF PERMITS BEING OBTAINED FOR REWIRING OR ANY INSPECTIONS BEING CALLED FOR.

DENIED FOR RECONNECTION OF POWER
1. WALLS EVENTUALLY TO BE REMOVED FOR INSPECTIONS
2. PRIOR TO ANY INSPECTIONS BEING CALLED FOR AND APPROVED. PLAN FOR REMODEL TO BE OBTAINED FOR ALL NEW WORK AT DEVELOPMENT SERVICES.
04/06/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TO RESOLVE DNR VIOLATION ISSUE
2) WORK WITHOUT PERMITS
3) CONTRACTOR ON RECOED "OLD TOWN" 400-7589
04/05/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
SEE NOTES LAST INSP, NO COMPLIANCE
04/04/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. SEE NOTES LAST INSP.
2. UNIT #'S MUST BE ON UNITS AS WELL AS PERMITS
3. SATISFY DNR VIOLATION ON RECORD
4. OPEN PERMIT FOR GENERAL REPAIRS?
04/03/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
* DNR HAS VIOLATION ON THIS PROPERTY - 3 UNITS ?? WORK WITHOUT PERMITS - COMBO PERMIT FOR GEN. REPAIRS NO INSPECTIONS.

1. OUTSIDE SECURITY LIGHT ON WEST ROOF OVERHANG NEEDS TO BE A WEATHERPROOF INSTALLATION.
2. EXPOSED ROMEX ON EAST OUTSIDE WALL NEEDS TO BE PHYSICALLY PROTECTED PER NEC - ABOVE BASEMENT DOOR
3. EXPOSED WIRING & SPLICES UNDER ROOF OVERHANG ON WEST SIDE OF HOUSE.

DOOR LOCKED - HOWEVER INSIDE APPEARS TO BE GUTTED OUT WITH EXPOSED STUDS.

OBTAIN PROPER PERMITS FOR ALL TRADES WORK INVOLVED YOU CAN OBTAIN A TEMP CONST. POWER UNDER THE PROPER REMODEL PERMIT.

CALLED 444-7319 PER REQUEST LEFT MSG.
INSTALL ADDRESS #'S ON UNITS -- 2 DWELLINGS ON PROPERTY