Permit: T07EL00368

Parcel: 122184090


Addresses:

3549 E BELLEVUE ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
05/28/2009 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
1) WALLS CHECKED WIRES OK
2) GROUND BOXES OK
3) SMOKE DETECTORS OK
4) BONDING AND WASHER CIRCUITS OK
5) CALL BACK FOR FINAL
05/15/2009 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
2 GROUND RODS NEEDED
BOND GAS LINE
CUT 2 HOLES TO SEE WIRES
CALL BACK FOR REINSPECTION
UPGRADE PANEL TO 200 AMPS
07/18/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK INTERIOR ELECTRICAL COVER
07/16/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. CEILING DRY WALLED BEFORE APPROVAL - OPEN FOR INSPECTION
2. INSTALL NAIL PLATES WHERE HOLE IS LESS THAN 1 1/4" FROM STUD FACE
3. GROUND METAL BOXES
4. SMOKE DETECTORS TO BE MINIMUM 6" DOWN FROM CEILING ON WALL & 36" FROM HVAC VENTS
5. WHERE ARE WASHER/DRYER AND RANGE CKT'S
6. ATTIC ACCESS TO BE 24 X 24 - PROTECT ROMEX WITHIN 6' OF ACCESS
7. YOU WILL NEED TO BOND WATER & GAS PIPES