Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/30/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 02/23/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NEED A PERMIT FOR SERVICE UPGRADE ALSO, 2. MAST ABOVE ROOM WILL REQUIRE 2 LISTED & APPROVED GUY BACK BRACES & LEVEL RISER. 3. GROUNDING SYSTEM FOR SERVICE REQUIRES 2 RODS 6' APART PLUS WATER & GAS BOND GROUND WIRE TO BE BURNED AT LEAST 2" 4. RISER TO BE SUPPORTED BELOW SERVICE ALSO, 5. SMOKE DETECTORS REQUIRED IN BEDROOMS 6. INSTALL ALL MISSING FIXTURES 7. KITCHEN COUNTER RECEPTACLES BY SINK TO BE GFI 8. HOUSE NOT OWNER OCCUPIED NEED AN ELECTRICAL CONTRACTOR TO REDO SERVICE. |