Permit: T07EL00139

Parcel: 135081000

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
03/29/2007 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection :*
03/02/2007 ELECTRIC - SERVICE UPGRADE Partial Approval IVRS - Inspection :*
1) CALL FOR INSPECTION AFTER TEP TIE IN
02/28/2007 ELECTRIC - SERVICE UPGRADE Partial Approval IVRS - Inspection :*
1. WATER & GAS BONDING TO TERMINATE AT NEW SERVICE GROUNDING ELECTRODE SYSTEM PER 250 NEC
2. BRACE FOR RISER CONDUIT MUST BE A LISTED ASSEMBLY
SMASHED ENDS ON EMT CONDUIT NOT APPROVED