Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - SERVICE UPGRADE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/07/2007 | ELECTRIC - SERVICE UPGRADE | Approved | IVRS - Inspection :* | |
| 02/22/2007 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. #4 GROUND TO TERMINATE IN LOAD SIZE OF SERVICE 2. BRACE FOR RISER CONDUIT MUST BE LISTED HOMEMADE NOT APPROVED |
|
| 02/15/2007 | ELECTRIC - SERVICE UPGRADE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NEED TO INSTALL A LISTED AND APPROVED GUY BACK SUPPORT -- RIGID CONDUIT TYPE. 2. NEED TO INSTALL SERVICE ENTRANCE CONDUCTORS IN RISER TO SERVICE. 3. CANNOT HAVE 3 GROUND WIRES UNDER ONE LUG. 4. GROUND SYSTEM NOT INSPECTED - CANNOT USE PICTURE 5. GROUND WIRES BELOW SERVICE NEED TO BE SUPPORTED 6. NEED TO INSPECT DRYER OUTLET AND DRYER CONDUIT TO BE SUPPORTED WITHIN 3' OF PANEL. 7. WHERE IS PERMIT FOR ADDITION? PLEASE POST 8. WATER BOND AND GAS BOND TO BE #4 CU |