Inspection History: ELECTRIC - FINAL
Permit Number - T07EL00095
Inspection Description - ELECTRIC - FINAL
Inspection Status - Not ready for Inspection
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/24/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
01/24/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. REMOVE BOND SCREW IN SUB-PANEL - NEC 250.24 A 5 2. INSTALL ADDRESS ON PANEL - CITY 3. PROVIDE ARC FAULT PROTECTION FOR SMOKE DETECTORS NEC 210.12 B 4. SECURE/SUPPORT ROMEX IN BASEMENT - NEC 334.30 5. EXTERIOR J-BOX IS OVERFILLED, ROMEX TO - NEC 314.16 BE CONNECTED TO METAL BOXES WITH A ROMEX CONNECTOR. 6. MAKE SURE ALL SWITCHES GROUNDED AND ALL FACEPLATE SCREWS INSTALLED, IDENTIFY WHITE USED AS HOT. IN ATTIC 1. PROTECT ROMEX BY ACCESS - NEC 334.23 2. STAPLE ROMEX INTO BOXES - NEC 334.30 |