Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/23/2007 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* CALL FOR FINAL INSP. WHEN ROMEX (2) TERMINATED INTO RECEPTACLE BOXES. |
|
| 01/22/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : There is no access to the site.| 920* COULD NOT GET MESSAGE, IVR SYSTEM NOT WORKING, GATE LOCKED, PLEASE RECALL INSP. |
|
| 01/17/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK SOUTH & WEST KITCHEN OUTLETS ROUGH NORTH & EAST CORNER RECEPTS IF OVER COUNTERTOPS NEED TO BE GFI PROTECTED, DO NOT USE BATHROOM RECEPT. CIRCUIT FOR THESE PER 210 NEC. PROTECT BARE GROUND OUTSIDE WALL TO SERVICE PANEL WITH RACEWAY, AT LEAST UP TO VENT IN ATTIC, SPLICE IN WALL MUST BE ACCESSIBLE. |
|
| 01/11/2007 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. GROUND METAL BOXES, OPEN J-BOXES FOR INSP. 2. SUB-PANEL NOT GROUNDED PER CODE WATER PIPING NOT INTENDED TO BE USED AS EQUIP. GROUND TO SUB-PANEL. RUN EQUIP. GROUND TO SERVICE PANEL MUST BE INSTALLED WITH RACEWAY OR CABLE PER CODE. SEPARATE GROUNDS & NEUTRALS. 3. APPROVED PLANS CALL FOR 20 AMP RECEPTS |
|
| 01/09/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : There is no access to the site.| 920* NEED ACCESS TO PANEL, INSIDE HOUSE TO INSPECT WIRING METHOD: RECALL INSPECTION WHEN ACCESS AVAILABLE. |