Permit: T07EL00021

Parcel: 129022810


Addresses:

2826 E EXETER ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
01/23/2007 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
CALL FOR FINAL INSP. WHEN ROMEX (2) TERMINATED INTO RECEPTACLE BOXES.
01/22/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
There is no access to the site.| 920*
COULD NOT GET MESSAGE, IVR SYSTEM NOT WORKING,
GATE LOCKED, PLEASE RECALL INSP.
01/17/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK SOUTH & WEST KITCHEN OUTLETS ROUGH
NORTH & EAST CORNER RECEPTS IF OVER
COUNTERTOPS NEED TO BE GFI PROTECTED,
DO NOT USE BATHROOM RECEPT. CIRCUIT FOR THESE
PER 210 NEC.

PROTECT BARE GROUND OUTSIDE WALL TO SERVICE PANEL WITH RACEWAY, AT LEAST UP TO VENT IN ATTIC, SPLICE IN WALL MUST BE ACCESSIBLE.
01/11/2007 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. GROUND METAL BOXES, OPEN J-BOXES FOR INSP.
2. SUB-PANEL NOT GROUNDED PER CODE
WATER PIPING NOT INTENDED TO BE USED AS EQUIP. GROUND TO SUB-PANEL. RUN EQUIP. GROUND TO SERVICE PANEL MUST BE INSTALLED WITH RACEWAY OR CABLE PER CODE. SEPARATE GROUNDS & NEUTRALS.
3. APPROVED PLANS CALL FOR 20 AMP RECEPTS
01/09/2007 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
There is no access to the site.| 920*
NEED ACCESS TO PANEL, INSIDE HOUSE TO INSPECT WIRING METHOD: RECALL INSPECTION WHEN ACCESS AVAILABLE.