Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date |
Description |
Inspector |
Results |
Comments |
| 11/20/2007 |
INSP - INITIAL CODE ENFORCMENT |
|
Approved |
WROTE NOV - WENT TO OWNERS RESIDENCE, EXPLAINED NOV, BAD OWNER SIGN. FOLLOW UP TO BE THIRTY DAYS - 12/24/07 |
| 11/19/2007 |
INSP - INITIAL CODE ENFORCMENT |
|
Approved |
WENT TO DSD DID RESEARCH - UNIT IS OUT OF COMPLIANCE. |
| 11/14/2007 |
INSP - INITIAL CODE ENFORCMENT |
|
Approved |
VISITED SITE, MET WITH TENANT, PROCEEDED WITH INSPECTION. FOUND AS FOLLOWS - BEDROOM ADDITION HAS NO WINDOWS FOR EGRESS, ELECTRICAL SUB PANEL IN CLOSET UNMARKED AND NOT ICC CODE, WATER HEATER IS NOT UP TO CODE - INSTALLED VENT PIPE NOT DOUBLE WALL, TPT DRAIN - NONE. VENT PIPE FOR SEWER LINE IS AT ABOUT 4' LEVEL AND DOES NOT EXTEND THRU ROOF, AIR CONDITIONER ADDED SUB PANEL IS LOCATED ABOVE SINK, NO COVER, DOUBLE LAYERED ON NEUTRAL, IMPROPER INSTALLATION ABOVE SINK, DRYER VENT GOES THRU WALL APPROXIMATELY 3' IN LENGTH. LOOKED IN PERMITS FLOOR PLAN DOES NOT MEET CURRENT FLOOR PLAN |