Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/20/2007 | INSP - INITIAL CODE ENFORCMENT | Approved | VISITED SITE FOR INITIAL INSPECTION ON 08-20-07 REGARDING MIN HOUSING ISSUES, MADE CONTACT WITH OCCUPANT, WENT OVER ISSUES REGARDING COOLING, COOLING HAD BEEN REPAIRED BUT HAD OTHER ISSUES. OCCUPANT ALLOWED DNR INSPECTOR TO CONDUCT INSPECTION. VIOLATIONS ARE AS FOLLOWS: FIRE SAFETY: SMOKE DETECTOR WAS CHECKED AND FOUND NOT TO BE WORKING. HEATING SYSTEMS: WALL FURNACE IN HALLWAY HAS BEEN YELLOW TAGGED BY SW GAS AND DEEMED INOPERABLE AND OTHER FURNACE TENANT STATED DOES NOT WORK. ELECRICAL SYSTEM: HAZARDOUS ELECTRICAL 1) APPEARS MODIFICATION HAVE BEEN DONE TO ORIGINAL TWO WIRE SYSTEM. TESTER WAS USED ON SEVERAL THREE PRONG RECEPTABLES AND FOUND SEVERAL RECEPTACLES WERE LACK EQUIPMENT GROUND. 2) EXTERIOR RECEPTACLES FOR WASHING MACHINE AND DRYER ARE LACKING REQUIRED WEATHER PROTECTION COVERS ALSO AT EXTERIOR TOGGLE SWITCHES 3) ILLEGALLY SPLICED ELECTRICAL CONDUCTOR FOR FAN IN DINING ROOM. 4) KITCHEN LIGHT FIXTURE LACKING REQUIRED COVER REQUIRES TO BE HARD WIRED. MECH SYSTEM: EXHAUST FAN HAS BEEN REMOVED INTERIOR FEATURES: BEDROOM DOOR IN A DETERIORATED DILAPIDATED STATE, MISSING DOOR STYLE AND DOOR SKIN IS RIPPED AND MISSING LATCHING HARDWARE EXTERIOR SURFACES WEATHER PROTECTION 1) LAUNDRY ROOM/STORAGE ROOM DOOR IN A DILAPIDATED CONDITION, DOOR RUNNER SPLINTERED AND SHREDDED WITH EXPOSED WOOD SURFACES. 2) BROKEN WINDOW IN FRONT MIDDLE BEDROOM NOTE: WILL CHECK FOR ELECTRICAL UPGRADE. PICTURES TAKEN. |