Inspection History Details
Inspection Status: Violation
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/03/2007 | INSP - INITIAL CODE ENFORCMENT | Violation | MODIFCATIONS TO ELECTRICAL DISCONNECT'S AND PLUMBING MODIFCATIONS WITHOUT PERMITS UNIT 1 (EXTERIOR INSPECTION) · THE HOT WATER HEATER IS SITTING ON THE EARTH · ENCLOSURE NOT PROPERLY INSTALLED AND NOT PROVIDING PROTECTION FOR THE UNIT. · THE HOT WATER HEATER IS BLOCKING A WINDOW OPENING OPENING. · NEW INSTALL OF COPPER WATER SUPPLY PIPING TO BOTH THE UNIT AND THE DWELLING. · ARMORED FLEX CONDUIT TO HOT WATER HEATER EXPOSED TO THE EXTERIOR (NOT EXTERIOR TYPE.) · ½ RACEWAY EXCEEDS 10 FEET NOT STRAPPED THE BUILDING UNIT 2 (EXTERIOR INSPECTION) · THE HOT WATER HEATER IS BLOCKING A WINDOW OPENING · NEW INSTALL OF COPPER WATER SUPPLY PIPING TO HOT WATER HEATER AND DWELLING. · ARMORED FLEX CONDUIT EXPOSED TO THE EXTERIOR (NOT EXTERIOR TYPE.) · ENCLOSURE NOT PROPERLY INSTALLED AND NOT PROVIDING PROTECTION FOR THE UNIT. · PVC PIPE PROVIDING HOT WATER TO DWELLING AND IS EXPOSE TO THE EXTERIOR. · THE HOT WATER HEATER IS SITTING ON THE EARTH. · ARMORED FLEX CONDUIT TO HOT WATER HEATER EXPOSED TO THE EXTERIOR (NOT EXTERIOR TYPE.) · NEW CONDUIT SUPPLYING POWER TO A/C WINDOW MOUNT UNIT · ELECTRICAL PANEL IS NOT ANCHORED TO THE EXTERIOR WALL PROPERLY. · THE GROUND TO THE SERVICE HAS BEEN CUT. · MISMATCH BREAKERS · ADDED CIRCUIT · NO MAIN SHUT OFF IN THE PANEL UNIT 3 (EXTERIOR INSPECTION) · NEW CONDUIT SUPPLYING POWER TO A/C WINDOW MOUNT UNIT · THE GROUND TO THE SERVICE HAS BEEN CUT. · MISMATCH BREAKERS · ADDED CIRCUIT · NO MAIN SHUT OFF IN THE PANEL · NEW INSTALL OF COPPER WATER SUPPLY PIPING TO HOT WATER HEATER AND DWELLING · HOT WATER HEATER HAS NO DISCHARGE PIPE · THE HOT WATER HEATER IS SITTING ON THE EARTH · THE UNIT IS NOT PROPERLY ENCLOSED UNIT 4 (EXTERIOR INSPECTION) · NEW INSTALL OF COPPER WATER SUPPLY PIPING TO HOT WATER HEATER AND DWELLING · HOT WATER HEATER HAS NO DISCHARGE PIPE · THE HOT WATER HEATER IS SITTING ON THE EARTH · THE UNIT IS NOT PROPERLY ENCLOSED · NEW CONDUIT SUPPLYING POWER TO A/C WINDOW MOUNT UNIT · THE GROUND TO THE SERVICE IS NOT ANCHORED PROPERLY. · MISMATCH BREAKERS · ADDED CIRCUIT · NO MAIN SHUT OFF IN THE PANEL UNIT 5 (EXTERIOR INSPECTION) · NEW INSTALL OF COPPER WATER SUPPLY PIPING TO HOT WATER HEATER AND DWELLING · HOT WATER HEATER HAS NO ENCLOSURE. · ARMORED FLEX CONDUIT TO HOT WATER HEATER EXPOSED TO THE EXTERIOR (NOT EXTERIOR TYPE.) · NEW CONDUIT SUPPLYING POWER TO A/C WINDOW MOUNT UNIT · THE GROUND TO THE SERVICE HAS BEEN CUT. · MISMATCH BREAKERS · ADDED CIRCUITS · NO MAIN SHUT OFF IN THE PANEL · IMPROPER BRUSHING ON THE DISCONNECT · MISSING FILLER ON DEAD FRONT · CONDUIT INSTALLED UNDER EVE AREA IMPROPER, EXPOSED ROMEX. WOOD MATERIAL IS BEING USE TO SUPPORT THE AIR CONDITIONING UNIT'S THE WOOD IS EXPOSE TO THE EXTERIOR. |