Case: T07DV06020

Parcel: 107141050


Addresses:

124 E JACINTO ST

Inspection Status: Violation

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
07/03/2007 INSP - INITIAL CODE ENFORCMENT Violation MODIFCATIONS TO ELECTRICAL DISCONNECT'S AND PLUMBING MODIFCATIONS WITHOUT PERMITS

UNIT 1 (EXTERIOR INSPECTION)
· THE HOT WATER HEATER IS SITTING ON THE EARTH
· ENCLOSURE NOT PROPERLY INSTALLED AND NOT PROVIDING PROTECTION FOR THE UNIT.
· THE HOT WATER HEATER IS BLOCKING A WINDOW OPENING OPENING.
· NEW INSTALL OF COPPER WATER SUPPLY PIPING TO BOTH THE UNIT AND THE DWELLING.
· ARMORED FLEX CONDUIT TO HOT WATER HEATER EXPOSED TO THE EXTERIOR (NOT EXTERIOR TYPE.)
· ½ RACEWAY EXCEEDS 10 FEET NOT STRAPPED THE BUILDING

UNIT 2 (EXTERIOR INSPECTION)
· THE HOT WATER HEATER IS BLOCKING A WINDOW OPENING
· NEW INSTALL OF COPPER WATER SUPPLY PIPING TO HOT WATER HEATER AND DWELLING.
· ARMORED FLEX CONDUIT EXPOSED TO THE EXTERIOR (NOT EXTERIOR TYPE.)
· ENCLOSURE NOT PROPERLY INSTALLED AND NOT PROVIDING PROTECTION FOR THE UNIT.
· PVC PIPE PROVIDING HOT WATER TO DWELLING AND IS EXPOSE TO THE EXTERIOR.
· THE HOT WATER HEATER IS SITTING ON THE EARTH.
· ARMORED FLEX CONDUIT TO HOT WATER HEATER EXPOSED TO THE EXTERIOR (NOT EXTERIOR TYPE.)
· NEW CONDUIT SUPPLYING POWER TO A/C WINDOW MOUNT UNIT
· ELECTRICAL PANEL IS NOT ANCHORED TO THE EXTERIOR WALL PROPERLY.
· THE GROUND TO THE SERVICE HAS BEEN CUT.
· MISMATCH BREAKERS
· ADDED CIRCUIT
· NO MAIN SHUT OFF IN THE PANEL

UNIT 3 (EXTERIOR INSPECTION)
· NEW CONDUIT SUPPLYING POWER TO A/C WINDOW MOUNT UNIT
· THE GROUND TO THE SERVICE HAS BEEN CUT.
· MISMATCH BREAKERS
· ADDED CIRCUIT
· NO MAIN SHUT OFF IN THE PANEL
· NEW INSTALL OF COPPER WATER SUPPLY PIPING TO HOT WATER HEATER AND DWELLING
· HOT WATER HEATER HAS NO DISCHARGE PIPE
· THE HOT WATER HEATER IS SITTING ON THE EARTH
· THE UNIT IS NOT PROPERLY ENCLOSED

UNIT 4 (EXTERIOR INSPECTION)
· NEW INSTALL OF COPPER WATER SUPPLY PIPING TO HOT WATER HEATER AND DWELLING
· HOT WATER HEATER HAS NO DISCHARGE PIPE
· THE HOT WATER HEATER IS SITTING ON THE EARTH
· THE UNIT IS NOT PROPERLY ENCLOSED
· NEW CONDUIT SUPPLYING POWER TO A/C WINDOW MOUNT UNIT
· THE GROUND TO THE SERVICE IS NOT ANCHORED PROPERLY.
· MISMATCH BREAKERS
· ADDED CIRCUIT
· NO MAIN SHUT OFF IN THE PANEL

UNIT 5 (EXTERIOR INSPECTION)
· NEW INSTALL OF COPPER WATER SUPPLY PIPING TO HOT WATER HEATER AND DWELLING
· HOT WATER HEATER HAS NO ENCLOSURE.
· ARMORED FLEX CONDUIT TO HOT WATER HEATER EXPOSED TO THE EXTERIOR (NOT EXTERIOR TYPE.)
· NEW CONDUIT SUPPLYING POWER TO A/C WINDOW MOUNT UNIT
· THE GROUND TO THE SERVICE HAS BEEN CUT.
· MISMATCH BREAKERS
· ADDED CIRCUITS
· NO MAIN SHUT OFF IN THE PANEL
· IMPROPER BRUSHING ON THE DISCONNECT
· MISSING FILLER ON DEAD FRONT
· CONDUIT INSTALLED UNDER EVE AREA IMPROPER, EXPOSED ROMEX.

WOOD MATERIAL IS BEING USE TO SUPPORT THE AIR CONDITIONING UNIT'S THE WOOD IS EXPOSE TO THE EXTERIOR.