Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/18/2007 | INSP - INITIAL CODE ENFORCMENT | Approved | DAMAGE REPORT- BUILDING: REAR PORCH STRUCTURE, RAFTERS AND ROOF SHEATHING, BEARING AND NON BEARING WALLS AND T-III SIDING WERE DAMAGED BY FIRE. REAR DOOR DAMAGED BY TFD TO GAIN ENTRY. KITCHEN AND REAR BEDROOM HAVE SOM SMOKE DAMAGE. ELECTRICAL: ELETRICAL SERVICE PANEL APPEARS TO HAVE BEEN ADDED WITHOUT PERMITS. ADDED CIRCUIT FOR DRYER ON REAR PORCH WAS DAMAGED BY FIRE. HAZARDOUS WIRING ADDED TO REAR PORCH BURNED IN FIRE. POWER HAS BEEN DISCONNECTED, LEAVING STRUCTURE WITHOUT SERVICE. PLUMBING: GAS WAS SHUT OFF TO THE STRUCTURE DUE TO HOT WATER HEATER BEING IN THE MIDDLE OF LOCATION OF FIRE. PLUMBING LINES (GAS AND WATER) WERE NEVER PROPERLY SECURED AT THE BACK PORCH RUNNING TO WASHER AND HOSE BIB SET UP. MECHANICAL: NONE REMARKS: A PLUMBING EVALUATION WILL BE REQUIRED OF PLUMBING SYSTEM. ALSO A PERMIT WILL BE REQUIRED OF NEW 100 AMP SERVICE AND ADDED DRYER CIRCUIT PRIOR TO RE OCCUPYING THE STRUCTURE. |