Case: T07DV02030

Parcel: 107120640


Addresses:

306 E BLACKLIDGE DR

Inspection Status: Violation

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
03/23/2007 INSP - INITIAL CODE ENFORCMENT Violation FRONT UNIT IS OCCUPIED REAR UNIT IS VACANT
TWO METER SERVICE EQUIPMENT
UP GRADE
SERVICE EQUIPMENT (UNIT 306)
CHALLENGER PANEL BOX HAS

· MISMATCHED BREAKERS
· MISSING DEAD FRONT
· NO RECORD OF PERMITS FOR THE SERVICE UPGRADE

SERVICE EQUIPMENT UNIT 30
SQUARE D PANEL BOX HAS

· CONDUCTORS WERE CUT TO FIT INTO THE BACK FED OVER PROTECTION DEVICE

· MISMATCHED BREAKERS

· NO RECORD OF PERMITS FOR THE SERVICE UPGRADE

NEW AIR CONDITIONING UNIT INSTALLED.

NOTE:
REFERENCE
PERMIT T06EL00434
WITHDRAW STATUS
EXPIRED