Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/28/2007 | INSP - INITIAL CODE ENFORCMENT | Violation | NO SIGHS OF VEHICLES BEING REPAIRED. FRONT UNIT ADDED CIRCUIT TO SERVICE EQUIPMENT ADDITION TO SERVICE EQUIPMENT INSTALLATION OF UNPROTECTED ROMEX NEXT TO WALL AND ROUTED ABOVE GROUND SUPPLING POWER TO STORAGE SHED. PVC CONDUIT IMPROPERLY INSTALLED AND STRAPPED TO WALL, PLUMBING FITTINGS USE IN LIEU OF PROPER ELECTRICAL CONDUIT. ADDED BRANCH CIRCUIT OR FEEDER EXPOSED ROMEX EMERGING FROM PVC FITTING UNDER THE EAVER AND ENERGIZING A FLOOD LAMP OF UNKNOWN TYPE AND WATTAGE. REAR UNIT ADDED CIRCUIT FOR EXTERIOR RECEPTACLE, NON GFCI, EXPOSED UNPROTECTED ROMEX OVER FUSING OF CONDUCTOR IMPROPER WIRING METHODS AND MATERIAL ALL WORK WITHOUT PERMITS. |