Permit: T07CM04871

Parcel: 136200330


Addresses:

8132 E VICTORIA DR

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
01/31/2008 ROOF NAILING Approved IVRS - Inspection :*
01/29/2008 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
01/23/2008 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ANSWER AT NUMBER CALLED
2) NO SLAB OR FOOTING INSPECTION
3) MAKE UP ALL GROUND WIRES
4) INSTALL NAIL STOPS TO PROTECT WIRE WHERE MARKED WITH "X"
5) NEED APPROVED BEAM SIZE OF OVER GARAGE DOOR
6) NAIL OFF BRACED WALL PANELS AND ROOF 6" EDGES AND 12" IN THE FIELD
7) NEED 1/8" SPACE ON HORIZONTAL LINES BETWEEN ROOF SHEATHING. RUN A SAW BETWEEN SHEETS FOR EXPANSION