Permit: T07CM04797

Parcel: 141220290


Addresses:

8940 E RITA PARK DR


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T07CM04797

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/29/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
12/19/2008 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
RECEIVED BACTERIA REPORT & IN HOUSE BACKFLOW CERTIFICATIONS.

OLY REMAINING ITEM IS ADDITION OF SINK IN ROOM #129
ROOM 116 AS STATED ON 12/9/08 INSPECTIONS IS A TYPO ERROR ON PLUMBING PAGES.
12/17/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
COMPLETE ITEMS #1, #2 AND #7 FROM 12/09/08 INSPECTION
12/16/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
COMPLETE ALL ITEMS LISTED ON 12/09/08 HISTORY
12/09/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE CITY APPROVED PLAN FOR ADDITION OF SINK IN ROOM #116
2. PROVIDE APPROVAL OF SEPTIC SYSTEM FOR GUARD HOUSE
3. PROVIDE FEMALE ADAPTOR & THREADED PLUG
FOR 2-WAY C/O AT GUARD HOUSE
4. PROVIDE C/O PLUG FOR VENT FOR ACID WASTE DRAIN
5. PROVIDE HOSE BIB WITH VACUUM BREAKERS AT
HOSE REELS
6. FLOOR DRAIN IN TRUCKERS RESTROOM TO BE FLUSH TO FINISH TO AVOID TRIPPING HAZARD
7. PAINT ROOF VENT TERMINATIONS TO AVOID SUN DAMAGE 8. BACKFLOW CERTIFICATIONS & BACTERIA REPORT ON SITE
12/08/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PLEASE CALL IN ALL PLUMBING INSPECTIONS FOR APPROVAL ON THIS ACTIVITY CARD
2. THIS INSPECTION FOR GUARD HOUSE ONLY, PROVIDE CORRECT DRAINAGE FOR PAN DRAIN AND T&P DRAIN FOR WATER HEATER
12/01/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
11/14/2008 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1. RESTROOMS #305, #306, #405 AND #302
2. COMPLETE INSTALL IN 301, PROVIDE CLEAN BACTERIA REPORT AND BACKFLOW CERTS.
10/31/2008 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
THIS INSPECTION IS FOR ADMINISTRATION AREA ONLY
1. EXPOSE CLEANOUT IN ROOM #129
2. COMPLETE INSTALL OF APPLIANCES REQUIRING BACKFLOW PROTECTION
3. PROVIDE BACKFLOW PROTECTION FOR UPSTAIRS COFFEE MACHINE IN ROOM #208
4. MAKE EWC's WATER TIGHT AT WALL 1ST & 2ND LEVEL RESTROOMS OK ADMIN. AREA ONLY

RECEIVED BACTERIA REPORT FOR POTABLE WATER
10/23/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
CHLORINE INTRODUCED INTO SYSTEM AND FLUSHED AWAITING BACTERIA REPORT FOR ADMINISTRATION AREA WEST HALF OF BLD.