Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T07CM04788

Parcel: 105110700


Addresses:

4370 N ORACLE RD

Inspection Status: Not ready for Inspection

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
02/27/2008 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1. WHY HAS THE PLUMBER STUBBED UP TWICE AT P-9
2. AT P-4 REQUIRE 2X THE PIPE DIAMETER BETWEEN THE TRAP WEIR AND THE POINT OF VENT
3. WET SOILS INDICATE A LEAK
4. SUGGEST SHOOTING FLOOR LEVEL AND UPSTREAM MANHOLE COVER TO VERIFY NEED FOR B.W VALVE
5. OK TO START BACKFILLING
02/27/2008 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
CORRECTION MADE OK
OK TO COVER ALL AREAS