Permit: T07CM04781

Parcel: 131010260


Addresses:

4844 E 22ND ST

Inspection Status: Approved

Inspection History: PLUMBING - PROGRESS

Date Description Inspector Results Comments
03/26/2008 PLUMBING - PROGRESS Approved IVRS - Inspection :*
03/25/2008 PLUMBING - PROGRESS Not ready for Inspection IVRS - Inspection :*
1. SEE 705.1.1 2006 UPC CAULKED JOINTS
2. PROVIDE LISTING FOR 3" SPIGOT FLANGE
3. CONTRACTOR TO PAY REINSPECTION FEE
03/21/2008 PLUMBING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. STACKING CLOSET FLANGES IS NOT AN ACCEPTED METHOD OF INSTALLATION
2. CONTINUED "NOT READY" WILL RESULT IN A
REINSPECTION FEE
03/20/2008 PLUMBING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
CLOSET FLANGE TO BE SECURED FIRMLY TO FINISH FLOOR RESTING WITH TOP OF FLANGE 1/4" ABOVE FINISH FLOOR, WITH SMOOTH INTERIOR WATER WAY, RISER PIPE TO BE FLUSH WITH TOP OF CLOSET FLANGE OR PROVIDE A DUTCHMEN PIECE PROPERLY INSTALLED.