Inspection Status: Approved
Inspection History: PLUMBING - PROGRESS
Permit Number - T07CM04781
Inspection Description - PLUMBING - PROGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/26/2008 | PLUMBING - PROGRESS | Approved | IVRS - Inspection :* | |
03/25/2008 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1. SEE 705.1.1 2006 UPC CAULKED JOINTS 2. PROVIDE LISTING FOR 3" SPIGOT FLANGE 3. CONTRACTOR TO PAY REINSPECTION FEE |
|
03/21/2008 | PLUMBING - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. STACKING CLOSET FLANGES IS NOT AN ACCEPTED METHOD OF INSTALLATION 2. CONTINUED "NOT READY" WILL RESULT IN A REINSPECTION FEE |
|
03/20/2008 | PLUMBING - PROGRESS | Denied | IVRS - Inspection : See detailed listing on site.| 999* CLOSET FLANGE TO BE SECURED FIRMLY TO FINISH FLOOR RESTING WITH TOP OF FLANGE 1/4" ABOVE FINISH FLOOR, WITH SMOOTH INTERIOR WATER WAY, RISER PIPE TO BE FLUSH WITH TOP OF CLOSET FLANGE OR PROVIDE A DUTCHMEN PIECE PROPERLY INSTALLED. |