Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM04756

Parcel: 141351530

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM04756

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
02/19/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/15/2008 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED BECAUSE OF SNOW
02/14/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HOLDOWNS MISSING
2) ANCHOR BOLTS MISSING
3) STRAP BEAM TO POST FRONT OF HOUSE
4) NAIL OFF THA422 AT STAIRWAY HEADER
5) NAIL OFF SHEAR PANELS BETWEEN HOUSE AND GARAGE PER 303/508 DETAIL
6) NEED A SET OF PLANS WITH ROOF PLAN
7) NEED LADDER TO ACCESS ROOF
02/13/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL BOTTOM CHORDS BY JACK RAFTERS TO TOP PLATES
2) NAIL BELLY BAND WEST SIDE
3) NAIL GABLE END TO TOP PLATES OF BOTTOM CHORD
4) ANCHOR BOLTS THROUGHOUT
5) CANCELLED BY MARK